Retractable Tube Sampler.blow line samplers

 

APPLICATIONS

The Model RT-RTA2 automatically samples process streams that are under either positive or negative pressure. Accurate, frequent samples from pneumatic lines or conveyors are obtainable on-stream without interruption of the pneumatic conveying system. Fully automatic, all functions are easily adjustable. Installation can be on round or flat surfaces, horizontal or vertical lines, regardless of material flow direction. Adaptable for use in gravity flow systems as well as pressurized lines, it may be mounted on rectangular or round ducts and pipelines, or through the wall of a tank or hopper. Size and frequency of samples is completely adjustable. The Model RT-RTA2 will sample granules, powders, chips, flakes, pellets, and certain liquids and slurries.

 

FEATURES

The basic Model RT automatic sampler discharges the sample by an air motor-driven auger. With the Model RTA2 the sample is ejected by a controlled jet of air. In either ejection system, the sample is completely discharged. There is no carry-over, no degradation of product. The Model RT-RTA2 sampler has a simple, maintenance-free design. There is no metal-to-metal contact between parts. Completely explosion-proof, it is all air operation.

 

SPECIFICATIONS

ENGINEERING DATA
Power Requirements 35 to 60 psi compressed air for sampler operation. 110 V, 50 Hz, single phase current required for controls. Other voltages available
Actuators Double-acting air cylinder for sampling tube extension. Speed controlled gear head air motor for Model RT auger drive
Sampling Tube 1 1/2″ OD with sampling slot as required. Stainless steel is standard. Tube extension from 4″ to 6″
Auger 1 3/8″ dia. x 1 1/2″ pitch stainless steel
Sample Outlet 1 1/2″ OD stainless steel, plain end
Seals, Bearings and Packing Teflon®, Nylon®, Delrin®, or Urethane, as required
Housing, Spool, Mounting Flange Aluminium, stainless steel available
Air Fittings 1/4″ NPT
Mounting Flange Standard 150# 2″ pipe flange drilling. Flat-faced 5″ OD, furnished with gasket. For mounting on round surfaces, a round mounting adaptor is required and is available as an option
Enlargement Transitions Optional and recommended when mounting sampler in lines smaller than 4 inches
Control Panel IP 65 Enclosure with MSC Controller.
Weight Sampler, approx. 20kg; Control Panel, approx. 10kg.