Uses / Function: The FlowJam detects all types of bulk solid flows with
regard to material movement. The FlowJam distinguishers between the following
conditions:
- Material Flow
- Material jam/standstill or empty pipe
The FlowJam is available in 2 versions:
- Model 20.002 for sensing distances >200mm
- Model H20.0100 for sensing distances >2000mm
Applications:
-
Monitoring
of raw meal cyclones in cement plants
-
Monitoring
of screw conveyors in gypsum plants
-
Monitoring
of plastic injection in steel plants
Installation:
The
installation of the FlowJam is made easy by the following ways:
Commissioning:
The FlowJam is a stand alone unit that is
adjustable for both switch sensibility and delay response from the FlowJam
casing.
Technical Data:
|
Sensor |
| Housing Material: |
Stainless Steel |
| Protection: |
IP65 |
| EX zones: |
Dust EX zone 22 Dust EX zone 20/22 (with
process adaptor) |
| Ambient Temperature: |
-20 to +60°C |
| Process Temperature: |
-20 to +80°C standard -20 to +220° with
process adaptor
Max 700°C with ceramic flange |
| Max Working Pressure: |
Max 1 bar standard Max 20 bar with process
adaptor |
| Power Supply: |
12 - 30vdc (-0/+15%) 12 - 24vac (-0/+15%) |
| Relay Output: |
42v ac/dc 2A ac/dc
50W/60va |
| Response Time: |
1 - 15secs (continuously adjustable) |
| Measuring Frequency: |
24.125GHz: ±100MHz |
| Weight: |
1.0kg |
| Dimensions: |
Casing 52Ø x 216 Long Thread G1½" x