Uses: The MaxxFlow is a measuring system specially developed for the
measurement of high flow rates. Due to its completely open cross-section and its
small height, the MaxxFlow is applicable everywhere, where so far only complex
mechanical solutions like impact weighers or sensing plate systems were
possible. The installation of the MaxxFlow is made in vertical and inclined
pipes.
Function:
In the
measuring pipe a homogeneous high frequency electromagnetic measuring field is
produced. Solids which are within this measuring field absorb the energy of this
alternating field which leads to the measurement of the conveyed material,
typically in kg/M³
System:
A complete measuring unit consists of the
following components:
Benefits:
-
ATEX Certified
-
Unlimited Flow Rates
-
Low Profile
-
Maintenance Free
-
Non-Contact Measuring
Technical Data:
|
Sensor |
| Housing: |
Stainless Steel or Powder Coated Inner
Diameter 150 - 200mm Flanged to DIN 2576 |
| Protection: |
IP65 ATEX cat 3 D |
| Ambient Temperature: |
-20 to +60°C |
| Medium Temperature: |
-20 to +80°C |
| Max Working Pressure: |
Max 1 bar |
| Weight: |
Depending on Diameter |
| Dimensions: |
DIN 150: 300 x 300 x 400 DIN 200: 200 x 344
x 400 |
| Accuracy: |
±2...5% in calibrated range |
| System Accuracy: |
0.1% |
|
Evaluation Unit |
| Supply Voltage: |
230 V, 50 Hz, 24 vdc 110vac Optional |
| Power Consumption: |
12W |
| Operating Temperature: |
-10 to +45°C |
| Enclosure Dimensions: |
320 x 225 x 320 (L x W x H) |
| Weight: |
Approx. 2.5kg |
| Interface: |
RS 485 Mod-Bus Protocol |
| Flow Rate Output: |
4 to 20mA - 0 to 20mA Load <500Ω |
| Velocity Output: |
4 to 20mA Load <500Ω |
|